4 | Model Nomenclature LV Heat Pump Series
LV Heat Pump Series8 733 944 336 (2016/09) Subject to change without prior notice
MODEL NOMENCLATURE
Figure # 1
Not all Options are available on all models.
//9 97& )/738% ;; 6$0;; ; ; $;; ; ;; ; ; 6%$

GENERAL ELECTRICAL OPTIONS (UP TO 5 AVAILABLE PER UNIT)
A-EMS RELAY
B-BLOWER MONITOR RELAY
C-COMPRESSOR MONITOR RELAY
D-PHASE MONITOR
E-PUMP/VALVE RELAY
G-BOILERLESS CONTROL
H-FLOW PROVING SWITCH
J-DISCONNECT SWITCH
K-FIRE ALARM RELAY/DUAL POWER
M-WIRE TO 208 V
X-AS DEFAULT FOR NON USED ELECTRICAL CODES
VOLTAGE
0 115/60/1
1 208-230/60/1
2 277/60/1
3 208-230/60/3
4 460/60/3
5 575/60/3
8 220-240/50/1
A 380-420/50/1
SIZE
007, 009, 012, 015,
018, 024, 030, 036,
041, 042, 048, 060,
070
LV
CABINET CONFIGURATION
HZ-HORIZONTAL
VT-VERTICAL
CF-COUNTERFLOW
COAX OPTIONS
C-COPPER
N-CUPRO-NICKEL
WATER CONNECTIONS
F-FRONT
B-BOTTOM
M-MARINE
RETURN AIR CONFIGURATION
L-LEFT
R-RIGHT
DISCHARGE AIR CONFIGURATION
T-TOP
S-STRAIGHT
E-END
B-BOTTOM
FAN/MOTOR OPTIONS
P-STANDARD PSC
A- CONSTANT AIRFLOW ECM
T-CONSTANT TORQUE ECM
AIR COIL
U-UNCOATED
D-DUOGUARD
REVISION LEVEL
B-CURRENT
ELECTRIC HEAT
(SINGLE POINT)
X-NONE
A-5kW
B-7.5kW
C-10kW
CABINET CONSTRUCTION
A-GALVANIZED STEEL/1/2” STANDARD 1.5LB DUAL DENSITY FIBERGLASS
C-A-GALVANIZED STEEL/1/2” CLOSED CELL FOAM
D-A-GALVANIZED STEEL/1/2” STANDARD 1.5LB DUAL DENSITY FIBERGLASS, EXTRA QUIET
F-A-GALVANIZED STEEL/1/2” CLOSED CELL FOAM, EXTRA QUIET
APPLICATION
T-TXV OPTION
S-STANDARD RANGE
G-EXTENDED RANGE
AIR FILTRATION
1- STANDARD THROWAWAY FILTER W/4 SIDED FILTER RACK
4-MERV8-2” W/4 SIDED FILTER RACK
5-MERV13-2” W/4-SIDED FILTER RACK
REFRIGERATION CIRCUIT OPTIONS
X-NONE
H-HOT GAS REHEAT-ON OFF
B-HOT GAS BYPASS
C-HOT GAS BYPASS WITH HOT GAS REHEAT
S-STRAIGTH COOL
CONTROLS
X-NONE
M-DDC(MULTI PROTOCOL)(BACNET, MODBUS, N2
L-DDC-LONWORKS
WATER FLOW CONTROL OPTIONS
X-NONE
2-2 WAY SOLENOID VALVE
3-MEASURE FLOW (3GPM/TON)
4-2 WAY SOLENOID +MEASUREFLOW
6-WATER REGULATING VALVE CONNECTION
TRANSFORMER
4-40 VA
5-50 VA
7-75 VA
1-100 VA
STANDARD/SPECIAL
S-STANDARD
A-SPECIAL #1
B-SPECIAL #2
AGENCY OPTIONS
X-ETL (UL 1995)
C-CE (50 HZ ONLY)
E-ETL W/E-HEAT AND SINGLE POINT POWER
ECONOMIZER
X-NONE
E-ECONOMIZER WITH 3 WAY VALVE AND CONTROLS
CODE STRING LEVEL
CHANNEL
B-BOSCH