-19-
Inserting and Releasing Battery Pack
Slide charged battery pack (Fig. 11, 44) into the battery bay
(39) until the battery pack locks into position.
Your tool is equipped with a secondary locking latch to pre-
vent the battery pack from completely falling out of the bat-
tery bay, should it become loose due to vibration.
To remove the battery pack, press the battery pack release
button (38) and slide the battery pack completely out of the
battery bay.
Assembly
Attaching the Base Extensions
Attach each base extension to the left and right side of the
base:
1. Place the base extension (Fig. 9, 16) flush against the
base.
2. Using the Torx wrench (Fig. 7, 41) and the Torx screws
provided (Fig. 9 and Fig. 10), attach the base extension
(16) to the base.
3. Using the Torx wrench (Fig. 7, 41), tighten both Torx
screws until the base extension is fully seated against the
base (Fig. 10). Then tighten both Torx screws another
1/8 turn.
NOTE: To avoid overtightening and damaging the threads of
the Torx screws, tighten the Torx screws by hand with the
Torx wrench (41). Do not use a power screwdriver or impact
wrench on the Torx screws.
38
39
44
Fig. 11
Fig. 9
16
Torx screws
Fig. 10
16
Torx screws

Table of Contents