Off state
Indicates there is a power failure to the receiver. Check the wire connections for proper
wiring.
LEDs
The receiver utilizes an external LED indicator to status the operation of the receiver. Refer to
the table below for LED descriptions.
LED condition Pattern description
On (Normal) Indicates the receiver is functioning normally.
Off Indicates there is a power failure to the receiver, or that the
receiver is not wired correctly.
Continuous Flash: 1 sec
On, 1 sec Off
Indicates the receiver is being programmed with the zone and
transmitter ID’s from the compatible control panel.
Turns Off momentarily Indicates the receiver obtained a valid transmission from a
RADION transmitter.
Continuous Flash: A 3-
pulse signal, followed by
a short delay at the end
of the 3
rd
pulse
(Communication error)
Indicates the receiver has experienced a communication error
and/or a self-test failure. This error could be a result of either:
– A communication failure between the control panel and
receiver, or
– An invalid address switch setting.
Continuous Flash: A
continuous pulse
between On and Off
states (Trouble state)
– Indicates the receiver is in a trouble state, experiencing a
radio frequency interference failure.
– A communication failure with internal hardware components
within the receiver
Flash 3 times: Indicates the receiver has obtained a new radio frequency ID
while in “Learn Mode”.
Specifications (B810)
Housing dimensions (H x L x D) 209.60 mm x 139.70 mm x 31.80 mm
(8.25 in x 5.50 in x 1.25 in)
Power/voltage 10 -14 VDC, 12 VDC nominal
Maximum current draw 70 mA
Device testing To ensure proper functionality, the device
must be tested at least once every year by an
installer.
Operating environment 0゚C to +49゚C (+32゚F to +120゚F)
Relative humidity Up to 93% non-condensing
Frequency 433.42 MHz
Wiring distance Maximum distance of 243 m (800 ft) from the
control panel
3.4.1
3.5
22 en | RADION receiver SD RADION receiver SD
2014.03 | 06 | F.01U.261.834 Reference Guide Bosch Security Systems, Inc.