EasyManua.ls Logo

Bosch Radion B810 - Hand Clap Test; Low Battery; Wall Tamper Tab; Maintenance

Bosch Radion B810
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The specified range of the sensor has been established for worst-case conditions. While the
sensor will likely function at additional range, it may miss a minimum output break, or room
acoustics may change at some future time, bringing the sensor range back into normal 20 ft.
(6 m) conditions. Do not exceed the rated range of the sensor, regardless of what the tester
shows.
Hand clap test
Operational status of the glassbreak can be verified by performing a simple hand clap test to
ensure proper functionality of the sensor.
Performing the hand clap:
1. Hand clap loudly under the sensor. The LED blinks twice.
2. Verify that the LED blinks twice.
3. Performing this simple test verifies that the microphone is operating, and that there is
power to the sensor.
Low battery
When a low battery state is detected, the detector measures the battery, and sends a report
to the receiver/control panel.
Wall Tamper Tab
Use the wall tamper tab to activate an alarm when the glass break has been removed from the
wall.
Maintenance
Clean the cover with a damp (water) cloth as needed to keep it free of dust and dirt. Always
test the sensor after cleaning it.
5.2.2
5.3
5.4
5.5
RADION receiver SD RADION glassbreak | en 31
Bosch Security Systems, Inc. Reference Guide 2014.03 | 06 | F.01U.261.834

Table of Contents

Other manuals for Bosch Radion B810

Related product manuals