Transportand storage 29/64
RE92035-01-B/2019-11-25, A4VG Series35, Bosch Rexroth AG
For questions regarding repair and spare parts, contact your proper BoschRexroth
service partner or the service department of the manufacturer's plant of the axial
piston unit, seechapter 10.5 "Spare parts" on page52.
An uninstalled axial piston unit must be preserved with corrosion protection for the
duration of storage.
The following instructions only refer to axial piston units operated with hydraulic
fluid on a mineral oil basis. Other hydraulic fluids require other specific
preservation measures. In such a case, consult your local contact person; you can
find their contact information at
www.boschrexroth.com/addresses
BoschRexroth recommends the following procedure:
1. Clean the axial piston unit; seechapter 10.1 "Cleaning and care" on page50.
2. Drain the axial piston unit.
3. For storage times up to 12 months: Moisten the inside of the axial piston unit
with mineral oil and fill with approx. 100 ml mineral oil.
For storage times up to 24 months: Fill the axial piston unit with VCI 329
corrosion protection (20 ml).
Fill through the drain port T
1
or T
2
; see chapter7.4 "Installing the axial piston
unit", Fig. 13 on page40.
4. Plug all ports so they are airtight.
5. Coat unpainted areas of the axial piston unit with mineral oil or suitable,
easilyremovable corrosion protection, e.g.acid-free grease.
6. Pack the axial piston unit with desiccant airproof in corrosion protection film.
7. Store the axial piston unit in a shock-proof manner; see"Requirement" on
page28 in this chapter.
After removal