32/64 Installation
Bosch Rexroth AG, A4VG Series35, RE92035-01-B/2019-11-25
7.3 Installation position
The axial piston unit can be installed in the following positions. The pipeline routing
shown illustrates the basic layout.
If filling the stroking chambers via X
1
and X
2
is not possible in the final installation
position, then fill before installation, e.g.,in installation position2.
To prevent unexpected actuation and damage, bleed all air out of the stroking
chambers via the ports X
1
or X
2
, depending on the installation position.
7.3.1 Below-reservoir installation (standard)
Below-reservoir installation means that the axial piston unit is installed outside of
the reservoir below the minimum fluid level.
Recommended installation position: 1 and 2.
X
2
,X
1
T
2
S
h
t min
h
min
SB
1 2 3
4 5
T
1
X
1
, X
2
S
R
SB
h
t min
h
min
SB
h
t min
h
min
T
2
S
T
1
h
min
SB
X
2
S
X
1
h
t min
h
min
X
2
T
2
SB
S
X
1
R
R
F
1
F
2
F
2
h
t min
F
1
F
2
Fig. 9: Below-reservoir installation A4VG with installation positions 1–5
T
1
, T
2
Drain port X
1
, X
2
Control pressure port
F
1
, F
2
Filling/air bleeding h
t min
Minimum required immersion depth
(200mm)
R Air bleed port h
min
Minimum required distance to
reservoir bottom (100mm)
S Suction port SB Baffle (baffle plate)