7.6.3 Electrical connection of the product
WARNING
High electrical voltage!
Risk of severe injury or death from electric shock.
Disconnect the relevant system component before performing any maintenance
or repair work.
Secure the system against being unintentionally switched on again.
• Choose control and sensor elements in accordance with ENISO13849. Factor in
the load being transported and the transport speed.
• The motor may only be connected by qualified personnel!
• Comply with VDE regulation VDE0100 for Germany, or corresponding regulations
in the country of use.
Motor connection
• Observe the available line voltage!
• Observe the electrical power requirement shown on the motor nameplate,
seeFig. 10 on page20.
• Connect the motor in either awye or adelta configuration in accordance with the
wiring diagrams, seeFig. 11 on page 20, and the wiring diagram in the terminal
box.
• The motor is fitted with abimetal temperature monitoring switch (potential-free
thermal contact, 230VAC, 300mA). Wire the motor so that it is de-energized
when the switch is triggered.
• Insert the cable so that it cannot get damaged during operation.
• Optional motor connection with plug (AT = S), seeFig. 12 on page 20.
Observe the back-up fuse!
Checking the rotational direction of the motor
• Let the system run for no more than 2 secs., then ensure the correct rotational
direction of the motor.
• Switch any two wires (U1, V1 or W1, seeFig. 11 on page20) to change the
motor's rotational direction.
Please note:
For motors that come with afitted plug, correct the rotational direction in the
control cabinet or at the socket contact (socket side). This makes replacement
easier.
ENGLISH