36/40 Technical data
Bosch Rexroth AG, MIT: BS 1/…, 3 842 563 815/2021-11
16 Technical data
• For dimensions, seesales catalog TS 1
• Maximum section load: 1.0 kg/cm support surface length
• Maximum permissible load: 30kg
Maximum permissible load for BS1, b = 160 mm, MA = M: 30kg
• Noise emissions: < 70dB (A)
16.1 Ambient conditions
• The transfer systems have been designed for stationary use in alocation that is
protected from the elements.
• Operating temperature: +5°C to +40°C
–5°C to +60°C at 20% reduced load
• Storage temperature –25°C to +70°C
• Relative humidity 5% to 85%, non-condensing
• Air pressure > 84 kPa, corresponds to an installation altitude
<1400 m above sea level
• Max. load capacity of floor: 1000kg/m
2
• At installation altitudes >1400m, the load values of the electric drives are
reduced by 15%.
• The area should be kept free of mold, fungus, rodents and other vermin.
• Do not install or operate in the immediate vicinity of industrial equipment
producing chemical emissions.
• Do not install or operate near sources of sand or dust.
• Do not install or operate in areas that are regularly subjected to high-energy
forces caused, for example, by presses or heavy machinery.
• Resistant to many media that are commonly found in manufacturing, such as
water, mineral oil, grease, and detergents. Contact your Rexroth representative
if you have any doubts about resistance to specific chemicals, such as test oil,
doped oils, corrosive detergents, solvents or brake fluid.
• Avoid prolonged contact with highly reactive acidic or alkaline materials.