CS351 | 3609929B45/2014-09 Bosch Rexroth AG 87/108
Commissioning
ENGLISH
The permissible installation position for the
Compact System is vertical.
During assembly, the Compact System
should have at least 10 mm space when li-
ned up and at least 300 mm space above it.
Fig. 27: Compact System distance dimensi-
ons (dimensions in mm)
7Commissioning
CAUTION
Overheating of the Compact System!
Damage to the Compact System caused
by overheating
Keep the air ways used for cooling at
the rear side of the system clear when
assembling the Compact System.
300
10
CAUTION
Risk of damage to persons and pro-
perty!
Commissioning of the Compact System
requires basic mechanical and electrical
skills.
No one except qualified personnel
(see “Personnel qualification” on
page 59) is authorized to commission
the system.
CAUTION
Loss of protection class IP 54 due to
missing seals and plugs!
Liquids and foreign bodies may penetrate
and damage the product.
Prior to commissioning make
sure that all dummy panels are in
place and that the front cover is
closed and locked.
CS351_zweispaltig - D.book Seite 87 Donnerstag, 2. Oktober 2014 8:36 08