9 Interfaces
9.1 General information
Material damages to electronics due to missing
functional earth!
NOTICE
Ensure that the functional earth is connected, as otherwise the electronics can
be destroyed by a potential difference between the operator display and the
control cabinet PC if the voltage supply is interrupted to only one device and es-
tablished again. A direct connection of the functional earth between operator
display and control cabinet PC is optimal. If the functional earth is connected to
a neutral point, the control cabinet PC and the operator display have to be con-
nected to this neutral point.
To avoid malfunctions, use only shielded cables and metallic or con-
ductive connector/coupling housings with large-area shield support.
9.2 Overview
The following connections are available at the control cabinet PC:
Labeling at the
housing
Connection type Connector type
(at the device)
Mating connector or cable
(from outside)
X10 PC voltage supply:
DC 24 V
Male connector ter-
minal PC4/3-G7.62
Socket terminal
PC4/3-G7.62
XDVI DVI monitor or analog monitor
(via adapter)
DVI(A) socket
(24-pin and 5-pin)
DVI connector
XSER CDI interface, data RJ45 socket, 8-pin RJ45 plug
(Twisted pair, 8-wire)
XVID CDI interface, image RJ45 socket, 8-pin RJ45 plug
(Twisted pair, 8-wire)
XETH1, XETH2 Ethernet interfaces
10/100/1000 Base-T
RJ45 socket, 8-pin RJ45 plug
(Twisted pair, 8-wire)
XUSB1 to XUSB6 USB interfaces USB socket, 4-pin,
type A
USB plug, 4-pin
Internal connections for extension cards
1, 2 slots or 4 slots (see "Availa-
ble slots per PC box type" on
page 19)
PCI/PCIe PCI/PCIe card
Bosch Rexroth AG
Interfaces
Control Cabinet PC
14/57
DOK-SUPPL*-VPB*40.3***-IT05-EN-P

Table of Contents