Loading...
5.9.8 Interconnection diagrams for ready-made hybrid cables used for DC
bus connection
KLC03 - KMV03 (RKH0802)
Applies to: RKH0802
KLC03 plug-in connector Bulk cable KMV03 plug-in connector
RHS0009/KM04 REL0015 RHS0026/CM04
Interconnection diagram
KLC03/KMV03 plug-in connector
Cable type L-End R-End
RKH0802 XG9 connector X103.1
Tab. 5-40: Parts of ready-made hybrid cables used for DC bus connection
KLC03 - KLC03 (RKH0803)
Applies to: RKH0803
KLC03 plug-in connector Bulk cable KLC03 plug-in connector
RHS0009/KM04 REL0015 RHS0009/KM04
Interconnection diagram
KLC03/KLC03 plug-in connector
Cable type L-End R-End
RKH0803 XG9 connector XG9 connector
Tab. 5-41: Parts of ready-made hybrid cables used for DC bus connection