EasyManua.ls Logo

Bosch rexroth IndraDrive Mi KMV03 - X50, E-Stop Input

Bosch rexroth IndraDrive Mi KMV03
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.2.5 X50, E-Stop Input
View Connection Signal name Function
Condition as supplied:
With jumpers at 1-2 and 3-4
4 24V
24V output for E-Stop input
1)
3 ______
E-Stop
Digital input for E-Stop
(isolated; active with input voltage "L")
2 0V
1 0V
0V output for E-Stop input
2)
The input complies with EN61131-2, type 1.
Input circuit (R1 = approx. 1k; R2 = approx. 7k4; C1 = approx. 10 nF; V1 = approx. 6 V; V2 = approx. 0.7 V):
Spring terminal (connector) Unit Min. Max.
Connection cable stranded wire
mm
2
0,5 1,5
Connection cable AWG 20 16
Allowed input voltage V -3 30
Input voltage "H" V 15 30
Input current "H" mA 2 15
Input voltage "L" V 0 5
Input current "L" mA 0 > 0,5
Input resistance 2,5
1) Exclusively use the 24 V output for the E-Stop input in conjunc‐
tion with the jumper from X50.3 to X50.4. Maximum power rat‐
ing: 15 mA.
2) Exclusively use the 0 V output for the E-Stop input in conjunc‐
tion with the jumper from X50.1 to X50.2. Maximum rating:
15 mA.
Tab. 6-8: Function, Pin Assignment, Properties
See also description of the E-Stop function: chapter "E-Stop function" on
page 240