A Servo drives evenly distributed over the entire drive line
B Servo drives evenly distributed at the end of the drive line
C Servo drives evenly distributed starting at 20% of the drive line
D Limit value A: hybrid cable length = 4 m with P
42V
= 507 W
Limit value B: hybrid cable length = 18 m with P
42V
= 489.5 W
Limit value C: hybrid cable length = 17 m with P
42V
= 489.5 W
l
total_max
Maximum allowed hybrid cable length of a drive line
P
42V
KMV output XD10 load (without cable losses)
Fig. 7-16: Maximum allowed hybrid cable length of a drive line
For exact calculations of the allowed hybrid cable lengths in limit
cases, please contact our sales representative.
The figure below shows P
N3(KMV)
(KMV power consumption from 24V supply)
depending on P
42V
(KMV output XD10 load).
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
235/407
Notes on project planning
R911335703_Edition 04 Bosch Rexroth AG