For the C
Y
and C
leak
capacitances of the components please see
the end of this chapter.
Mains filter: Sizing rule
C
Y_limit
≥ C
Y_sum
C
leak_limit
≥ C
leak_sum
C
Y_limit
: Limit value of mains filter regarding C
Y
C
Y_sum
: C
Y
sum of drive system
C
leak_limit
: Limit value of mains filter regarding
leakage capacitance
C
leak_sum
: Sum of leakage capacitances of
drive system
Tab. 14-8: Mains filter: Sizing rule
Mains filter: Limit values
Mains filter
C
Y_limit
[nF] C
leak_limit
[nF]
HNF01.2D-M900 4080 1100
HNF01.2D-F240 2450 290
HNF01.1A-H350 2040 450
NFD03.1 1200 100
NFE02.1
1)
378 90
KNK03 2200 226
1) Cannot be used with IndraDrive Mi; can only be used for sin‐
gle-phase operation (1 × 230 V AC, nominal current: 8 A)
Tab. 14-9: Mains filter: Limit values
C
Y_sum
C
Y_sum
= C
Y_KCU
+ C
Y_Hxx
+ k × [C
Y_KMS
+ C
Y_KSM
]
C
Y_sum
: C
Y
sum
C
Y_KCU
: C
Y
KCU
C
Y_Hxx
: C
Y
HMS/HMD or HCS sum
C
Y_KMS
: C
Y
KMS sum
C
Y_KSM
: C
Y
KSM sum
k: Hybrid cable damping factor
Tab. 14-10: C
Y_sum
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
377/407
Appendix
R911335703_Edition 04 Bosch Rexroth AG

Table of Contents

Other manuals for Bosch rexroth IndraDrive Mi KMV03