EasyManua.ls Logo

Bosch Rexroth IndraDyn S MS2N - Preparing Storage

Bosch Rexroth IndraDyn S MS2N
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Open the main switch
3. Ensure that the main switch cannot be accidentally switched on again
4. Disconnection plug connections
When exchanging the motor, close open plug sides of power connec-
tions with protection caps if moistening with coolant/lubricant or
soiling must be expected (allowed soiling degree according to EN
50178: 2).
5. Exchange the motor
Observe the machine manufacturer's instructions when exchanging
the motor mechanically.
6. Re-establish the plug connections
7. Re-establish the dimensional reference
Risk of accidents due to unintentional axis
movements!
WARNING
If servo axes are provided with an indirect position measuring system via
the motor encoder, the dimensional reference is lost after motor replace-
ment!
For this reason, the reference to the machine coordinate system must be
re-established.
9.3
Preparing storage
Before motors are stored, the protection covers on flange socket, shaft and in-
put openings for cooling water in case of liquid-cooled motors which were at-
tached on delivery must be re-attached.
When motors are liquid-cooled, completely discharge the coolant from the cool-
ing tubes (e.g., via purging the coolant holes with pressure air). This will prevent
frost damage at storage temperatures lower than 0 °C.
Bosch Rexroth AG
Disassembly and exchange
MS2N Synchronous Motors
84/95
DOK-MOTOR*-MS2N*******-IT03-EN-P

Table of Contents

Related product manuals