6.2.13 Ground connection
Optional, MS2N motors (other design "E") can be designed with an additional
ground connection. An additional connection clamp is provided on the motor
flange to connect the grounding conductor. The screw terminal block with
clamping bracket must be assigned in a suitable way.
Ground connection (screw
M5)
Nominal cross-section Connectable wires Tightening torque
4 mm²
4 mm² (finely stranded)
6 mm² (single stranded)
2 Nm
Tab. 6-24: Junction for grounding conductor