6.2.8 MS2N Electrical connection "C"
View terminal box "C” power, M17 encoder (double cable connection) / rotating
area
Connection
Power
Terminal box
Encoder
Flange socket
Connector size - M17
Output direction A-side / B-side rotatable (max. 10x)
Adjustment torque - 2 ... 6 Nm
Locking - SpeedCon
Tab. 6-19: MS2N..-.....-..C..-.....-.. Terminal box / flange socket
Pol pattern M17, encoder (double cable connection)
Designation
Function
Encoder
Ax Bx Cx Dx Hx
1 +UB +UB
2 n.c. n.c.
3 Data+ Data+
4 Data- Data-
5 A+ n.c.
6 A - n.c.
7 B+ n.c.
8 B - n.c.
9 GND GND
Tab. 6-20: Pin assignment pole pattern M17, encoder