6.2.9 SpeedCon connectors
Damage to persons or property by disconnect-
ing or connecting energized connectors!
● Connect and disconnect connectors only when they are dry and de-energized.
● During operation of the system, all connectors must be securely tightened or
locked.
Observe when connecting the flange sockets:
● Protect the flange sockets from external force effect.
● Connect the motor to ready-made connection cables.
Connect SpeedCon connectors
Properly measured ready-made connection cables are available. Plug connector
type, size, wire cross section
1. Insert power connector in position “open”.
2. "Manually" tighten the power connector with a rotation by approx. 90°.
3. Check the firm seat of the SpeedCon quick lock by short pull on the con-
nector.
4. Secure the cables, that accruing forces due to cable vibrations onto the
connector are prevented.
Bosch Rexroth AG
Assembly
MS2N Synchronous Motors
66/95
DOK-MOTOR*-MS2N*******-IT03-EN-P