Installation 27/54
3 842 358 814/2017-01, MIT: LU 2, Bosch Rexroth AG
8 Installation
8.1 Unpacking
f Lift the product from its packaging.
f Dispose of the packaging material in accordance with the national laws of
your country.
8.2 Installation requirements
f During installation the ambient conditions specifi ed in the technical data
(see page 53) must be maintained.
8.2.1 Installation position
f Install the product level and plumb at right angles and parallel to the axis.
This ensures proper functioning and prevents premature wear.
8.2.2 Mounting with T-bolts
Mount the transfer systems TS 1, TS 2plus, TS 2pv, TS 4plus, TS 5 and the chain
conveyor systems VarioFlow and VarioFlow S with T-head bolt and collar nut.
Make sure the T-bolt is in the correct position when inserting and tightening in the slot.
The notch at the end of the bolt indicates the orientation of the T-bolt.
f 1 = T-bolt insertion position in the slot.
f 2 = T-bolt clamping position in the slot.
f Tightening torque: 25 Nm (M8).
8.3 Required tools
Hex head cap screw SW13.
Hex socket head cap screw SW3, SW4, SW5, SW6.
Cross recess screwdriver PZ2
Rubber mallet
Spirit level
Expanding pliers
Cutter to shorten the lubrication line.
21
ENGLISH
358814_2017_01_EN.indd 27 16.01.2017 13:38:19