11.4.3 Motor Connection according to American Standard (UL)
MKE037, -047, -098
(1) MKE with connection cable (single conductor)
(2) Steel tube NPT ¾ inch (not included in the scope of delivery)
(3) Ex terminal box (not included in scope of delivery)
(4) Lead the connection cable into the steel tube
Fig.11-9: Electrical connection MKE037, -047, -098 UL
The machine manufacturer is responsible for observing the respec‐
tively valid standards and regulations.
Apply the shield in the Ex-terminal box as described in the docu‐
mentation DOK-GENRL*-EMV********-PRxx-EN-P.
Interconnect the single conductors after the mechanical assembly within the Ex
terminal box according to the terminal diagram (Fig. 8-5).