Standard Edition Title Concordance
DIN IEC 60721-1 1997-02
Classification of ambient conditions - Part 1: Environmental
parameters and their severities (IEC 60721-1:1990 + A1:1992
+ A2:1995); German version EN 60721-1:1995 + A2:1995
EN 60721-1(1995-04);
EN 60721-1/
A2(1995-07);
IEC 60721-1(1990-12);
IEC 60721-1 AMD
1(1992-12); IEC 60721-1
AMD 2(1995-04)
DIN VDE 0170/0171-
9
1988-07
Electrical equipment for potentially explosive areas; Casting
capsule "m"; German version EN 50028:1987
EN 50028(1987-02)
IEC 60072-1 1991-02
Dimensions and power series for rotating electrical machines;
Part 1: Housing sizes 56 to 400 and flange sizes 55 to 1080
IEC 60072-2 1990-12
Dimensions and power series for rotating electrical machines;
Part 2: Housing sizes 355 to 1000 and flange sizes 1180 to
2360
IEC 60072-3 1994-03
Dimensions and power series for rotating electrical machines;
Part 3: Small built-in motors; flange size BF10 to BF50
IEC 60364-4-41 2003-04
Construction of low-voltage installations - Part 4-41: Protec‐
tion for safety; Protection against electric shock (IEC 64/1272/
CDV:2002)
IEC 721-1 see DIN IEC 60721-1
IEC 721-3-3 see DIN EN 60721-3-3
UL 1446 1997-05 Insulation material systems - General
UL 508C 2002-05 Static converter
UL 674*ANSI 674 1994-04
Electric motors and current generators for potentially explo‐
sive (classified) areas
Fig.14-1: List of Standards
14.2 Selection of Connection Cable
14.2.1 Power Cable IndraDyn S MKE
Motor
IndraDrive
DuraDrive
1)
Cross-section
[mm²]
HCS02._W0012
HCS02._W0028
HMD01._W0012
HMD01._W0020
HMD01._W0036
HMS01._W0020
HMS01._W0036
HCS02._W0054
HCS02._W0070
HCS03._W0070
HMS01._W0054
HMS01._W0070
HDC01._A040N HDC01._A100N
MKE037B-144 □ IKG4145 IKG0309 □ 1
MKE047B-144 □ IKG4145 IKG0309 □ 1
MKE098B-047 □ IKG4145 IKG0309 □ 1
MKE098B-058 □ IKG4145 IKG0309 □ 1
Project Planning Manual | Rexroth MKE Synchronous Motors Electric Drives
and Controls
| Bosch Rexroth AG 121/131
Appendix