When fitting the drag chains with cables of varying diameters (> ±20 %)
use chains with divided chambers or racks. When fitting the drag chains
with multi-layered cables, mount bars between the layers.
Fig.8-11: Multi-layer allocation of drag chains
Before fastening the cables within the drag chains, move them at least 10
to 20 times. This relaxes the cables and brings them into a neutral position.
After the machine has been operated for approx. 24 hours, readjust the
cables.
Fasten both ends of the cables. The minimum distance is 30 times the
cable diameter measured from the end point of the bending motion. Fasten
the cables across a large area of the outer jacket. The inner wires (core)
must only be slightly squeezed. If the cables are squeezed strongly, their
service life will be shortened.
Project Planning Manual | Rexroth MKE Synchronous Motors Electric Drives
and Controls
| Bosch Rexroth AG 71/131
Connection Technique