EasyManua.ls Logo

Bosch Rexroth SB24/34 - Connecting Plate (C3)

Bosch Rexroth SB24/34
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
About these products 25/78
RE 66170-B/2019-05-15, Control block SB24/34, Bosch Rexroth AG
5.3.8 Connecting plate (C3)
Table 11: External ports
Position Designation Information
LS signal output
LS signal input optional:1, 2, 3, 4, 5
, ,
Tie rod bore
Block mounting thread
Table 12: Internal functions
Position Designation Information
Shuttle valve with spring pretension optional
RfBR bridge optional
The C3connecting plate is used for SBx4blocks with central connecting plate.
Shuttle valve with spring pretension
: Discharges the higher LS pressure from the
block-internal channel Y and
to port . The spring pretension prevents pressure
build-up in
if port is not occupied.
RFB-R bridge
: Relieves the RfB return line for block-internal return flow R.
The C3connecting plate is not equipped with manual operating elements or external
control functions.
Application
Internal function
Operation / control
Fluid plan

Table of Contents

Related product manuals