26/78 About these products
Bosch Rexroth AG, Control block SB24/34, RE 66170-B/2019-05-15
5.3.9 Connecting plate for variable pump (C6)
Table 13: External ports
Position Designation Information
Pressure reducing valve control port optional
Inlet port optional
Return flow optional
LS signal input optional:1, 2, 3, 4, 5
LS signal output
EHS pilot oil pressure diagnosis optional
, ,
Tie rod bore with thread
Block mounting thread
Table 14: Internal functions
Position Designation Information
Shuttle valve with spring pretension optional
Pressure relief valve optional
Rx-R non-return valve optional
Pressure reducing valve optional
Pressure reducing valve switchable solenoid optional
Threaded plug optional
The C6connecting plate is used for SBx4blocks with or without central connecting
plate.
Shuttle valve with spring pretension
: Discharges the higher LS pressure from the
block-internal channel Y and
to port . The spring pretension prevents pressure
build-up in
if port is not occupied.
Pressure relief valve
: Limits the pressure at port and indirectly also the
pressure in the block-internal P line.
NOTICE! The pressure relief valve with its short response time and low flow is
applied for limitation of the pressure peaks in the supplied flow.
Application
Internal function