60/78 Installation
Bosch Rexroth AG, Control block SB24/34, RE 66170-B/2019-05-15
7.6.6 Customer-specific coupling connection
Item Designation Use Information Number
Directional valve
Coupling housing
O-ring PortA and B 24.5×2.15 2
Socket-head screw M6 4
The coupling connections are customer-specific and deviate from the illustration.
Installation of customer-specific coupling flange:
1. Insert the O-rings
into directional valve ports and .
2. Align coupling housing
with flange surface to the directional valve .
3. Align coupling housing
and the mounting bores with the coupling mounting
threads
in directional valve .
4. Tighten the coupling housing
with the four socket-head screws at the
coupling port
of directional valve .
5. Tighten socket-head screws
. Tightening torque M
A
=11
+1
Nm.