EasyManua.ls Logo

Bosch Rexroth SB24/34 - 6.2 Storage Requirements

Bosch Rexroth SB24/34
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Transport and storage 53/78
RE 66170-B/2019-05-15, Control block SB24/34, Bosch Rexroth AG
6.2 Storage of control block/control block segment
The storage areas must be free from corrosive materials, vapors and gases.
To prevent damage to the seals, ozone-forming equipment (e.g.,mercury-vapor
lamps, copiers, printers, high voltage equipment, electric motors, sources of
electrical sparks or electrical discharge) must not be operated in storage areas.
The storage areas must be dry and free from dust.
Ideal storage temperature: +5 °C to +20 °C.
Min. storage temperature: –20 °C.
Max. storage temperature: +40 °C.
UV protection: 100%
Avoid significant exposure to light (e.g. bright windows or direct fluorescent
lighting).
Relative humidity (no condensation): max. 65%.
Do not stack control blocks/control block segments and store them protected
against collisions.
Do not store the control block/control block segment on sensitive attachments,
e.g., actuation elements, sensors, solenoids, or valves.
Do not remove protective covers and protective plugs.
Check the control block/control block segment monthly to ensure proper storage.
The maximum permissible storage time is two years.
Delayed commissioning, long freight and storage times or a prolonged shutdown of
Rexroth control blocks/control block segments leads to corrosion. Take additional
corrosion protection measures to prevent this.
Warranty entitlement will be rendered void if the requirements and storage
conditions are not adhered to or after expiration of the maximum storage time.
Recommended procedure after longer storage times:
1. Check the entire control block/control block segment for damage and corrosion
prior to installation.
2. Perform a test run to check the control block/control block segment for proper
function and leak-tightness.
3. External seals of control blocks/control block segments that have been stored for
longer than 12months are to be checked for damage before installation and may
need to be replaced.
4. If the storage period of two years is exceeded, external seals must be replaced.
After expiration of the maximum storage time, we recommend having the control
block/control block segment inspected by the responsible BoschRexroth
servicepartner.
In case of any questions regarding repair and spare parts, please contact the
responsible BoschRexroth service partner or the service department of the
controlblock/control block segment manufacturer's plant, see chapter10.4
"Spareparts" onpage69.
Requirements
After delivery

Table of Contents

Related product manuals