RE 30126-B/09.13 | Installation and Operation Hydraulics | Bosch Rexroth AG 19/32
Installing the VRPD 2
2.8 Connecting the valve position transducer
Connection for the valve position transducer is shown in the following illustration.
VPC D
_
06
3
42
1
Valve position
f
eedback connection
z12
z14
z16
z18
z10
Fig. 5 Connecting the valve transducer
The transducer is connected using a 4-pole cable connector Pg7-G5W1F, which can
be ordered separately under material number R900023126.
Cable 4 x 0.25 mm² of type LiYCY-CY ( 4 x 30 AWG Double shielded cable) is rec-
ommended for lengths up to 50 m.
The shield should be connected to z10 on the edge connector of the controller on the
supply side only.