Installation, Operation and Maintenance Manual
SM Series Heat pump
6 720 220 406 (2015/02)
SM024 | SM036 | SM048 | SMO60 | SM070

Table of Contents

Other manuals for Bosch SM036

Questions and Answers

  • C
    christopherrussellSep 4, 2025
    What to do if the fan on my Bosch SM036 Heat Pump isn't working?
    • C
      crystal47Sep 4, 2025
      If your Bosch Heat Pump's ECM constant airflow motor isn't operating, there could be several reasons. First, check for 24 VAC between "G" and "C" and verify all wiring connections, as there may be no fan operation signal. Loose wiring can also cause this issue, so check all wiring connections at the motor and control box, ensuring that power and control harnesses are securely connected. Interface board problems could also be the cause; make sure the interface board isn't damaged and that all DIP switches are in the proper configuration. Finally, a faulty motor could be the problem; check the supply voltage to the motor and ensure all motor wires are secure.
  • E
    emitchellSep 13, 2025
    What to do if my Bosch SM036 Heat Pump unit turns off on high pressure control?
    • D
      Daniel JohnsonSep 13, 2025
      If your Bosch Heat Pump is turning off due to the high-pressure control, the discharge pressure might be too high. In 'COOLING' mode, this could be due to a lack of or inadequate water flow, the entering water temperature being too warm, or a scaled or plugged condenser. In 'HEATING' mode, it could be due to a lack of or inadequate airflow, an inoperative blower, or clogged filters or restrictions in the ductwork. Another cause might be that the unit is overcharged with refrigerant, requiring you to reclaim refrigerant, evacuate, and recharge with the factory-recommended charge. Finally, check for a defective or improperly calibrated high-pressure switch.
  • D
    Dennis PorterSep 2, 2025
    Why is my Bosch Heat Pump blowing warm air in cooling mode?
    • J
      Jessica CarterSep 2, 2025
      If your Bosch Heat Pump is providing excessively warm air in cooling or excessively cool air in heating, several factors could be responsible. The airflow might be too high; consult the blower performance table and reduce fan speed if possible. High or low water temperature could also be a cause; check the unit's capacity versus the water temperature. Air leakage in the ductwork can also lead to this issue, so inspect the ductwork. Finally, a loss of refrigeration capacity could be the reason; in that case, check refrigerant pressures with a gauge set.
  • E
    Elizabeth AndersonSep 15, 2025
    Why does my Bosch Heat Pump unit short cycle?
    • V
      victoria15Sep 15, 2025
      If your Bosch Heat Pump is short cycling, it could be due to several reasons. The unit might be oversized, requiring you to recalculate the heating or cooling loads. The thermostat could be installed near a supply air grill, in which case you should relocate it and readjust the heat anticipator. Also, check the wiring and controls for a defective or improperly calibrated low-pressure switch.
  • M
    Michelle ChaseSep 14, 2025
    What to do if the blower operates but the compressor does not in my Bosch Heat Pump?
    • S
      Shannon BallSep 15, 2025
      If the blower in your Bosch Heat Pump is running but the compressor isn't, first check the thermostat's settings, calibration, and wiring. Inspect the safety controls for loose or broken wires at the compressor, capacitor, or contactor. If the compressor is cool and the overload won't reset, the compressor may need to be replaced. A compressor motor grounded internally to the shell also requires compressor replacement; if there's a compressor burnout, install a suction filter dryer. Finally, if the compressor windings are open after the compressor has cooled, check their continuity; if they're open, replace the compressor.
  • P
    Phillip MeyerSep 18, 2025
    Why does my Bosch SM036 Heat Pump keep short cycling?
    • J
      John BarnesSep 19, 2025
      If your Bosch Heat Pump is short cycling, it might be oversized; recalculate the heating and cooling loads. The thermostat could be installed near a supply air grill; relocate it. Readjust the heat anticipator. Check for a defective or improperly calibrated low-pressure switch.
  • J
    John LeeDec 1, 2025
    Why is my Bosch SM036 Heat Pump providing insufficient cooling or heating?
    • B
      Benjamin WhiteDec 1, 2025
      If your Bosch Heat Pump isn't providing enough cooling or heating, several factors could be at play. First, ensure adequate airflow and proper air distribution, and replace any dirty filters. Check for leaks in the ductwork or ambient air entering through doors or windows. If the unit is undersized, recalculate the heating or cooling loads; adding insulation and shading might help. A low refrigerant charge can also cause inefficient operation, so check that. Other potential causes include a defective compressor (check if the discharge is too low and suction pressure is too high), a defective reversing valve, or a restricted or defective TXV. Compare unit operating pressures to the unit's pressure/temperature chart. Lastly, the refrigerant system may be contaminated with moisture or noncond...
  • A
    Ann CrawfordAug 28, 2025
    What to do if my Bosch Heat Pump is not running at all?
    • B
      btaylorAug 28, 2025
      If your Bosch Heat Pump isn't running, start by checking the power supply. Ensure the disconnect is closed and power is applied. Inspect for blown fuses or tripped breakers, replacing or resetting them as necessary, ensuring correct fuse size. Verify the voltage supply meets the unit's data plate specifications; if it's low, contact your local power company. Also, examine the thermostat. Set the fan to 'ON' to see if the fan runs. Test 'COOL' and 'HEAT' modes with extreme temperature settings to check for proper operation. If issues persist, confirm 24 volts at the low-voltage terminal strip between 'R' and 'C,' 'Y' and 'C,' and 'O' and 'C,' and between 'G' and 'C' in the air handler. Replace the thermostat if it's defective.
  • S
    Sharon BradleyAug 27, 2025
    Why does my Bosch Heat Pump unit shut off on low pressure control?
    • L
      Levi BarreraAug 27, 2025
      If your Bosch Heat Pump shuts off due to low pressure control, it could be caused by several factors. In cooling mode, this may be due to a lack of or inadequate air flow, entering air temperature being too cold, an inoperative blower, a clogged filter, or restrictions in the duct work. In heating mode, it may be due to a lack of or inadequate water flow, entering water temperature being too cold, or a scaled or plugged condenser. Also, the unit could be low on refrigerant, requiring you to check for a refrigerant leak, repair it, evacuate, and recharge with the factory-recommended charge. Finally, check for a defective or improperly calibrated low-pressure switch.
  • A
    amy26Aug 25, 2025
    What to do if my Bosch SM036 compressor isn't working?
    • J
      Julie CoxAug 26, 2025
      If the compressor on your Bosch Heat Pump isn't operating but the fan is running, it could be due to an open compressor overload. Check for supply voltage at the load side of the contactor. For 3-phase models, check the phase rotation and voltage at all 3 phases. Poor wiring connections can also cause this; look for signs of heat on the wiring insulation and ensure that all wiring connections are secure and properly torqued. A burned-out compressor is another possibility; check if the compressor hums when power is applied. If not, check the resistance of the compressor windings using the values shown in the compressor characteristics chart, ensuring the compressor is cool (70° F) when checking the windings.

Summary

Key to Symbols

Safety Warnings

Crucial safety precautions for installation and servicing of the heat pump equipment.

Model Nomenclature

General Description

Factory Installed Options

Lists available options like HGRH, Electric Heat, and HRP.

Moving and Storage

Initial Inspection

Location

Configurability

Horizontal Configurability

Instructions for reconfiguring the blower orientation on horizontal units.

Counter-Flow Configurability

Vertical Configurability

Access to Internal Components

Steps required to gain access to the unit's internal parts.

Return and Discharge Duct Flanges

Pre Installation Unit Preparation

Corner Cap Installation

Instructions for applying corner caps to the unit cabinet.

Mounting Vertical Units

Mounting Horizontal Units

Hanging Bracket Kit

Condensate Drain

Duct System

Piping

Water Quality

Electrical

Safety Devices and UPM Controller

Explains safety controls and the Unit Protection Module.

Freeze Sensor

ECM Interface Board

Thermostat Outputs

Lists terminal functions for thermostat connections.

Airflow Selector

Describes how to adjust airflow settings.

Dehumidification Method Selector

Explains selection of dehumidification modes.

Constant Torque Motors (ECM)

Options

Hot Gas Reheat (HGRH)

Explains the HGRH dehumidification option.

Electric Heat

Details on supplemental electric heat options.

Heat Recovery Package (HRP)

Description of the HRP for heating potable water.

Constant Airflow Motor

DPS Water Flow Proving

Pump Relay

Comfort Alert Module

Smart Start Assist

Mode of Operation

Explains operating modes and LED indications for SSA.

Heat Recovery Package

Water Tank Preparation

Steps for preparing the water tank for HRP connection.

Initial Start-Up

Sequence of Operation

Describes unit operation in cooling and heating modes.

Cooling Mode

Heating Mode

Application Considerations

Well Water Systems

Guidance for using well water with the heat pump.

Cooling Tower;Boiler Systems

Considerations for using cooling towers or boilers.

Geothermal Systems

System Checkout

Unit Start-Up

Procedures for starting the unit and verifying operation.

Maintenance

Unit Check-Out Sheet

Troubleshooting

UPM Board LED Indications

Interpreting LED blink codes for UPM board faults.

Unit Troubleshooting

Table of common problems, causes, and solutions.

Compressor Ohms

Comfort Alert Module - Flash Codes

HRP Troubleshooting

Smart Start Assist LED Status Indication

Electronic Thermostat

Operating Temperatures and Pressures

Airflow Tables

Constant Airflow Motor Airflow Table

Water Side Pressure Drop Table

Wiring Diagrams

Wiring Harness Drawings

Specific harness connection diagrams for motor types.

Spare Parts List

Vertical (VT)

Spare parts specific to Vertical configurations.

Horizontal (HZ)

Spare parts specific to Horizontal configurations.

Counter Flow

Spare parts specific to Counter Flow configurations.

Dimensional Drawings

Horizontal - Supply Air Configuration: End Blow

Dimensions for horizontal units with end blow supply air.

Horizontal - Straight Through

Dimensions for horizontal units with straight through supply air.

Horizontal - Hanging Bracket Location

Specifications for hanging bracket placement.

Counter Flow

Dimensions for Counter Flow units.

CF - Vertical

Dimensions for Counter Flow units in Vertical configuration.

Bosch SM036 Specifications

General IconGeneral
BrandBosch
ModelSM036
CategoryHeat Pump
LanguageEnglish