Shutdown
Gaz 6000 W – 6720866247 (2019/07)
24
8Shutdown
8.1 Switching off/standby mode
The device has an anti-seizing function which prevents the heating pump
and the 3-way valve seizing up following long periods of inactivity.
The anti-seizing function remains active during standby mode.
Switch off the device with the K key.
The display shows only the symbols and .
If the device is taken out of operation for a long period: Bear in mind
frost protection ( chapter 8.2).
8.2 Setting frost protection
NOTICE:
Risk of damage to the system from frost!
The heating system can freeze up after a prolonged period (e.g. during a
power failure, switching off the power supply, faulty fuel supply, boiler
fault etc.).
Ensure that the heating system is in constant use (particularly when
there is a risk of frost).
Frost protection for the heating system:
Frost protection for the heating system is only ensured if the heating
pump is operational and is pumping heating water through the entire
system.
Leave the heating switched on.
Set the maximum flow temperature to at least 40 °C (Section 7.4).
-or- If you want to leave the device switched off:
mix Bosch-approved anti-freeze into the heating water ( Tab.,
page 16) and drain the DHW circuit.
For further information, see the heating controller operating
instructions.
Device frost protection:
The device frost protection function switches the burner and heating
pump on when the temperature in the installation room (at temperature
sensor for heating flow) falls below 5 °C. This prevents the boiler freezing
up.
Activate summer mode ( chapter 7.8) or set the device to standby
mode ( chapter 8).
NOTICE:
Heating system at risk through frost.
In summer/standby mode, only the device is protected against frost.
Frost protection with OpenTherm controllers:
In order to protect the heating system against frost, adjust the
controller to a minimal setback temperature of 10 °C.
The controller must not be switched off or set to stand by.
8.3 Anti-block protection
This function prevents the heating pump and the 3-way valve seizing up
following long periods of inactivity.
The anti-seizing function remains active during standby mode.
Every time the pump is switched off, a timer is started that briefly starts
the heating pump after 24 hours.