EasyManua.ls Logo

Bosch WBN 6000-24 CR - Menu 3; Restoring Values to Default Setting

Bosch WBN 6000-24 CR
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Settings in the service menu
29
Gaz 6000 W – 6720866247 (2019/07)
Table 19 Menu 2
11.2.3 Menu 3
Press the + key and key simultaneously until the display shows
L.1.
Press + key until the display shows L.3.
Press key to make the settings in menu 3 (L.3).
Press + key or to scroll through this menu's service functions.
Default settings are shown in bold in the following table.
Table 20 Menu 3
11.2.4 Restoring values to default setting
To restore all values from service levels 1 and 2 to their default settings:
Select service function 2.8E in the second service menu and save
value 1. The appliance starts in the default setting.
2.0A Gas type for appliance type 00: Appliance for natural gas
01: Appliance for LPG
This service function allows you to set the gas
type.
In the case of a conversion, 2.bd is set to 00.
2.0b Ionisation current When the burner is running:
–≥1 A = OK
–<1 A = fault
With burner switched off:
–<1 A = OK
–≥1 A = fault
Service function Settings/adjustment range Comment/Restriction
Service function Settings/adjustment range Comment/Restriction
3.1A Appliance type, performance This service function allows you to adjust the control device to the
appliance output. This is necessary when the control device is
replaced.

Table of Contents