Settings in the service menu
29
Gaz 6000 W – 6720866247 (2019/07)
Table 19 Menu 2
11.2.3 Menu 3
▶ Press the + key and – key simultaneously until the display shows
L.1.
▶ Press + key until the display shows L.3.
▶ Press key to make the settings in menu 3 (L.3).
▶ Press + key or – to scroll through this menu's service functions.
Default settings are shown in bold in the following table.
Table 20 Menu 3
11.2.4 Restoring values to default setting
To restore all values from service levels 1 and 2 to their default settings:
▶ Select service function 2.8E in the second service menu and save
value 1. The appliance starts in the default setting.
2.0A Gas type for appliance type • 00: Appliance for natural gas
• 01: Appliance for LPG
This service function allows you to set the gas
type.
In the case of a conversion, 2.bd is set to 00.
2.0b Ionisation current – • When the burner is running:
–≥1 A = OK
–<1 A = fault
• With burner switched off:
–<1 A = OK
–≥1 A = fault
Service function Settings/adjustment range Comment/Restriction
Service function Settings/adjustment range Comment/Restriction
3.1A Appliance type, performance – This service function allows you to adjust the control device to the
appliance output. This is necessary when the control device is
replaced.