2.5 Dimensions and minimum clearances
Fig. 2 Dimensions and minimum clearances (mm)
Table 3 Wall thickness S depending on the diameter of the flue
accessories
Table 4 Clearance A depending on the flue accessories for horizontal
flue pipe
≥ 100
700
200
150
≥ 100
B
0010011833-001
32
65
65
102
R
1
/
2
60
30
R
3
/
4
R
1
/
2
R
3
/
4
R
3
/
4
A
Ø100
Ø60
634
68
≥ 100
S
K
345
400
300
Wall thickness
S
K [mm] for Ø flue accessories [mm]
Ø 60/100 Ø80 Ø 80/125
15 - 24 cm 130 110 155
24 - 33 cm 135 115 160
33 - 42 cm 140 120 165
42 - 50 cm 145 145 170
Flue gas accessories A [mm]
Ø 60/100 mm
Connection elbow Ø 60/100 mm
95
Ø 60/100 mm
Connection adapter Ø 60/100 mm,
elbow 90° Ø 60/100 mm
185
Ø80mm
Connection adapter Ø 60/100 mm with
combustion air supply, elbow 90° Ø 80 mm
198
Ø 80/80 mm
Separate pipe connection Ø 80/80 mm,
elbow 90° Ø 80 mm
180
Ø 80/80 mm
Separate pipe connection Ø 80/80 mm,
vertical condensate drain Ø 80 mm,
elbow 90° Ø 80 mm
265