Inspection and maintenance
37
Gaz 6000 W – 6720866247 (2019/07)
15.2.8 Checking electrical wiring
Check wiring for mechanical damage and replace faulty cables/leads.
15.2.9 Removing the DHW temperature sensor
CAUTION:
Water damage due to escaping water.
Close the tap at the cold water inlet.
Open DHW tap.
1. Remove the clip.
2. Lever out the DHW temperature sensor from below using a
screwdriver.
3. Disconnect the connector at the temperature sensor.
Fig. 36 Removing the DHW temperature sensor
15.2.10 Unblocking the pump (e.g. when commissioning the
system)
Flip the control device down ( page 18) to access the pump.
Undo cap [1].
A small amount of water may escape.
Turn shaft [2] with a screwdriver for approx. half a turn.
Screw in the cap again and flip the control device up.
Fig. 37
1.
0 010 005 992-001
3.
2.
0 010 005 993-001
1.
2.
2
1