EasyManua.ls Logo

Bosch WBN 6000-24 CR - Page 46

Bosch WBN 6000-24 CR
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
Gaz 6000 W – 6720866247 (2019/07)
46
Table 31 Technical Data
WBN 6000-35 ..
Unit Natural gas Liquid gas (LPG)
Heat output/load
Max. rated output (P
max
) 80/60 °C KW 35.0 35.0
Max. rated heat input (Q
max
) for heating KW 38.5 38.5
Min. rated output (P
min
) 53/47 °C KW 10.8 10.8
Min. rated heat input (Q
min
) for heating KW 11.6 11.6
Max. rated heat output (P
nW
) for DHW KW 35.0 35.0
Max. rated heat input (Q
nW
) for DHW KW 38.5 38.5
Gas supply value
Natural gas H (H
i(15 °C)
= 9.5 kWh/m
3
)m
3
/h 4.0
LPG (H
i
= 12.9 kWh/kg) Kg/h 2.92
Permissible gas supply pressure
Natural gas H mbar 17 - 25
Liquid gas (LPG) mbar 25 - 45
Expansion vessel
Pre-charge pressure bar 0.5 0.5
Total capacity l 8 8
Hot water
Max. DHW volume l/min 14 14
Specific flow T = 50 K l/min 9.6 9.6
Specific flow as per EN 13203-1 (T = 30 K) l/min 16.0 16.0
DHW temperature °C 35 - 60 35 - 60
Max. permissible DHW pressure bar 10 10
Min. flow pressure bar 0.3 0.3
DHW comfort class as per EN 13203 3 3
Calculation figures for calculating the cross-sectional area as per EN 13384
Flue gas temperature 80/60 °C, max. rated value °C 128 130
Flue gas temperature 53/47 °C, min. rated value °C 70 75
Flue gas mass flow rate, max. rated value g/s 22.0 23.8
Flue gas mass flow rate, min. rated value g/s 19.10 18.6
CO
2
at max. rated output % 6.8 - 7.3 7.7 - 8.2
CO
2
at min. rated output % 2.6 - 3.1 2.8 - 3.3
NO
x
content mg/kWh 143
NO
x
class 3
Flue gas connection mm 60/100 60/100
Approval data
Product ID no. CE-0085CO0060
Appliance category (gas type) II
2 H 3+
Installation type B
22
, C
12
, C
32
, C
52
, C
82
General description
Electrical voltage AC ... V 230 230
Frequency Hz 50 50
Max. power consumption (heating mode) W <150 <150
Standby power consumption W 5 5
Sound pressure level dB(A) ≤38 ≤38
IP rating IP X4D X4D
Max flow temperature °C 40 - 82 40 - 82
Max. permitted operating pressure (P
MS
) for heating bar 3 3
Permissible ambient temperature °C 0 - 50 0 - 50
Weight (unpacked) kg 39/40 39/40
Dimensions W × H × D mm 485 × 700 × 315 485×700×315