Commissioning
45
Greenstar 8000 Style – 6720883855 (2019/01)
6.11 Flue gas analysis
NOTICE:
Combustion testing
Combustion testing must be carried out by a competent qualified
person. Testing must not be attempted unless the person carrying
out the combustion check is equipped with a calibrated Flue Gas
Analyser conforming to BS 7967 and is competent in its use.
Flue gas analysis
Ensure that the gas inlet pressure has been checked and is
satisfactory.
Refit the test point plugs after the test has been completed.
The flue gas analysis performance of the appliance can be checked via
the flue turret/adaptor sample points.
Flue gas sample point location on flue turret/adaptor.
Fig. 69 Combustion test
[1] Flue gas sample point
[2] Flue turret flue gas blank plug
[3] Flue adaptor flue gas blank plug
6.12 Finishing commissioning
6.12.1 Fitting the combustion casing
Fig. 70 Fitting the combustion casing
Ensure this cover is engaged onto top bracket [1] before securing
screw [3].
6.12.2 Fitting the appliance casing
0010015569-001
1
3
2
0010023566-001
3.
2.
1.