Technical Specifications/Logs
Greenstar 8000 Style – 6720883855 (2019/01)
72
12.6 Setting values for central heating/DHW output
Table 31 GR8700iW 30 S NG
Table 32 GR8700iW 35 S NG
G20
(20 mbar)
Gross
calorific
value
H
S(0 °C)
[kWh/m
3
] 11.2
Net calorific
value
H
i(15 °C)
[kWh/m
3
] 9.5
Performance
[kW]
Load [kW] Display [%] Gas volume
[l/min at T
V
/T
R
= 80/60 °C]
4.9 5.1 17 9
6.0 6.3 21 11
7.0 7.3 24 13
8.0 8.4 28 15
9.0 9.5 31 17
10.0 10.6 35 19
11.0 11.7 39 21
12.0 12.8 42 22
13.0 13.9 46 24
14.0 15.0 50 26
15.0 16.2 54 28
16.0 17.3 57 30
17.0 18.5 61 32
18.0 19.6 65 34
19.0 20.8 69 36
20.0 21.9 73 38
21.0 23.1 77 41
22.0 24.3 80 43
23.0 25.5 84 45
24.0 26.7 88 47
25.0 27.9 92 49
26.0 29.1 96 51
26.9 30.2 100 53
G20
(20 mbar)
Gross
calorific
value
H
S(0 °C)
[kWh/m
3
] 11.2
Net calorific
value
H
i(15 °C)
[kWh/m
3
] 9.5
Performance
[kW]
Load [kW] Display [%] Gas volume
[l/min at T
V
/T
R
= 80/60 °C]
6.1 6.3 18 11
7.0 7.2 21 13
8.0 8.3 24 15
9.0 9.3 27 16
10.0 10.3 30 18
11.0 11.3 33 20
12.0 12.4 36 22
13.0 13.4 39 23
14.0 14.4 42 25
15.0 15.4 45 27
16.0 16.5 48 29
17.0 17.5 51 31
18.0 18.5 54 32
19.0 19.5 57 34
20.0 20.5 60 36
21.0 21.6 63 38
22.0 22.6 66 40
23.0 23.6 69 41
24.0 24.6 72 43
25.0 25.6 74 45
26.0 26.6 77 47
27.0 27.6 80 49
28.0 28.7 83 50
29.0 29.7 86 52
30.0 30.7 89 54
31.0 31.7 92 56
32.0 32.7 95 57
33.0 33.7 98 59
33.7 34.4 100 60