8.9.1 Checking the burner
1. Remove the combustion cover Fig. 62.
2. Unscrew the screws on the burner cover.
3. Remove the burner cover.
Fig. 76 Removing the burner cover
Remove the burner and clean its components.
Fig. 77 Burner
Reinstall the burner in reverse order, including a new gasket.
Install the burner and the burner cover.
Check the gas/air ratio.
8.9.2 Checking the non-return valve in the air-gas manifold
1. Unscrew the screws at the air-gas manifold.
2. Remove the air-gas manifold.
Fig. 78 Removing the air-gas manifold
1. Remove the non-return valve.
2. Check the non-return valve for contamination and cracks.
Fig. 79 Non-return valve in the air-gas manifold
Install the non-return valve.
Install the air-gas manifold.