22
M12/M15/M18
5 Settings and Optimum Operating Values 5
Machine
M12 M15
Distillation
Cooling water regulator condenser
°C
(°F)
45
(113)
45
(113)
Thermal sensor:
Cycle distillation OFF
°C
(°F)
133
(271)
133
(271)
Still stripping OFF
°C
(°F)
138
(280)
138
(280)
Residue draining
°C
(°F)
55
(131)
55
(131)
Thermal sensor, distilled solvent *
°C
(°F)
45
(113)
45
(113)
Restrictor in steam feeder
mm
(in)
6
(.24)
6
(.24)
Vacuum pressure control kPa minus 75 minus 75
Temp. sensor heater element (el.) °C(°F) 230 (446) 230 (446)
* at flash point >55°C (131 °F)