27
M12/M15/M18
6. Betrieb 6.
6.1.3. Refilling Solvent
Follow the procedure given in Point 6.1.2 for routine refilling of solvent.
Attention:
Even empty containers can still hold solvent residues.
Therefore, tightly seal the container (barrel) again and
store or dispose of in accordance with regulations!
6.1.4 Vacuum Pump
The vacuum pump does not need any operating liquid and starts automatically after the machine is
turned on.
6.1.5. Filling the Water Separator
Pump solvent from tank I to the still for about 15 seconds:
+ + + 15 seconds
+ + +
The distillation heating starts automatically. The distillation fills the water separator.
6.1.6. Filling the Economy Filter
Start filter maintenance program P46 (filter 1) or P47 (filter 2), starting with step „fill drum“:
+ + + + „fill drum“ +
You do not have to use filter powder!
PROG
5
9
START
STOP
C
C
PROG
HOLD
PROG
4 6
HOLD
START

Table of Contents