26
M12/M15/M18
6. Operation 6.
Execution:
Connect a hose between the barrel and ball valve .
Open the ball valve.
Start program P51:
+ + +
The tanks fill up, with one overflowing into the other.
Watch the level of the liquid in the tank at the sight-glass until the tanks are full enough.
Lift the suction line out of the barrel.
Close the ball valve.
Stop program P51 and leave:
+ + + +
Remove the hose connections to the barrel.
Put the screw cap on to the ball valve.
Close the barrel and store in accordance with regulations.
Depending on the filter you have, you may have to refill with solvent after you fill the filter.
If the barrel becomes empty during the filling, do the following:
Close the ball valve.
Stop program P51:
Change the barrel.
Open the ball valve.
Continue program P51:
With an additional 3rd tank:
- first fill up tank 1 and tank 2 (using program P51)
- fill tank 3 with P67
- fill tank 2 once more with P51