Ordering codes
VR06
–
□□□□
–
□□□
–
□□□
1 2 3 4 – 5 6 7 – 8 9 10
1 Power
4: 90-250 VAC, 47-63 Hz
5: 20-28 VAC, 47-63 Hz
6: 11-18 VDC
7: 18-36 VDC
8. 36-72 VDC
2 Analog Input Card
0: none
1: 1 channel withAI181 G: 3 channels with AI183V
2: 2 channels with AI182 H: 6 channels with AI183V
3: 3 channels with AI183
4: 4 channels with AI181 & AI183
5: 5 channels with AI182 & AI183
6: 6 channels with AI183
*See AI181/2/3(V) in Accessories below.
3 Digital Input Card
0: none
1: 6 channels
4 Digital Output Card
0: none
1: 6 relays 2: 12 relays
5 Communication
0: standard Ethernet interface
1: RS-232/422/485 ( three in one ) + Ethernet interface
6 PC software
1: Free basic software Observer I for non-communication application
2: Extensive software Observer II for communication of RS-232/422/485 or Ethernet
7 Firmware
1: with Mathematics, Counter & Totalizer & FDA 21 CFR part 11 compliance