900IW Series Integrated Welders
B.1
Electrical
Power Requirements - AC Input voltage and Current:
Model
Input Voltage
Input Current
9051W+
(export only)
910IW+
9201W+
100V AC, 50/60 Hz
245V AC, 50/60 Hz
115V AC, 50-60 Hz
100V AC, 50/60 Hz
200/245V AC, 50/60 Hz
7 amps
3.5 amps
13 amps
14 amps
7 amps
200/245V AC, 50/60 Hz 14 amps
Note:
All input voltages are single phase.
Electrical connection:
Model
Voltage
Plug
Receptacle
9101W
117
NEMA 5-15P (supplied)
NEMA 5-15R
9051W
100/200/245
None supplied
91orw
100/200/245
None supplied
9201W
200/245
NEMA L6-20P (loose)
NEMA L6-20R
Output Power
905IW+
910IW+ 920IW+
To converter *
500W
1000W
2000W
To load *
475W
950W
1900W
* 100% meter reading
Frequency:
20 kHz