3.2.5. Technical Data of Trip-Lines IV, V, VI
Maximum rating : 50 volts dc / 300 mamps.
Outputs are passive, short-circuit proof and free floating. They must be supplied externally.
3.2.6. Technical Data of Trip-Lines I, II, III
Maximum rating : 50 volts dc / 3 amps / 75 watts
Maximum rating for DC13-applications : 24 volts / 3 amps
Outputs are not short-circuit proof (permanent currents exceeding 8 amps will destroy outputs).
Impedance : 10 kohms versus L- (negative pole of power supply)
For inductive type loads, external spark extinguishing means must be provided.
Total response time (trip relays de-energize to trip) from trip event until trip circuits are in trip
condition : < 15 milliseconds.