EasyManua.ls Logo

Bresser 7002582 - Specifications; Console

Bresser 7002582
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
Temperature reading
too high in the day
time
1. Placethesensorinopenareaandatleast1.5mo󰀨theground.
2. Ensure that the sensor is placed away from heat generating
sources or structures, such as buildings, pavement, walls or air
conditioning units.
Some condensation
beneath the UV
sensor may occur
overnight
This will disappear when temperature rises up under the sun and will
nota󰀨ecttheperformanceoftheunit.
10. Specications
10.1 Console
General specication
Dimensions (W x H x D)
171 x 116 x 21mm (6.7 x 4.5 x 0.8 in) without attach table
stand
Weight 220g (with batteries)
Main power DC 5V, 1A adapter
Backup battery (optional) CR2032
Operating temperature range
-5˚C~50˚C
Operating Humidity range RH10~90%non-condensing
Support sensor
- 1 Wireless 7-in-1 weather sensor array
- 3 Wireless thermo-hygro sensor (optional)
RF frequency
(Depend on country version)
868Mhz (EU or UK version)
Time related function specication
Time display HH : MM
Hour format 12hr AM / PM or 24 hr
Date display DD / MM or MM / DD
Time synchronize method Internet time server
Weekday languages EN / DE / FR / ES / IT / NL / RU
Setup app
App name WSLink
App download platform Google play and Apple Store
Support platform Android smart phone or iPhone
WI-FI communication specication
Standard 802.11 b/g/n
Operating frequency : 2.4GHz
Supported router security
type
WPA/WPA2, WPA3, OPEN, WEP (WEP only support
Hexadecimal password)
Barometer (Note: Data detected by console)
Barometer unit hPa, inHg and mmHg
Measuring range
540~1100hPa
Accuracy
(700~1100hPa±5hPa)/(540~696hPa±8hPa)
(20.67~32.48inHg±0.15inHg)/(15.95~20.55inHg±
0.24inHg)
(525~825mmHg±3.8mmHg)/(405~522mmHg±6mmHg)
Typical at 25°C (77°F)
Resolution 1hPa / 0.01inHg / 0.1mmHg

Table of Contents