Loading...
13-3
SOLID STATE CONTROLLER TIPS
COMPLAINT CAUSE REMEDY
Display reads FAIL
1. There is a controller fail-
ure
1. Push power OFF button
Contact service person
Display reads HI
1. Oil temperature too high 1. Push power OFF button
Contact service person
Display reads PROB
1. There is a temperature
sensor probe failure
1. Push power OFF button
Contact service person
Display reads CHEC
1. Oil temperature not rising
properly
1a. Check wall fuse or circuit
breaker
1b. Push power OFF button
Contact service person
FROZEN IQF PRODUCT
Note:
This unit is not designed to cook 8 piece
cut chicken, whether fresh or frozen.
COMPLAINT CAUSE REMEDY
Product too light
1. Low oil temperature
2. Not done
3. Food basket overloaded
1. Check cook temperature
2. Increase cook time
3. Decrease load
Product too dark
1. High oil temperature
2. Overcooked
3. Oil old
4. Thawed and refrozen
1. Check cook temperature
2. Decrease cook time
3. Change oil
4. Keep product at 0°F or
below
Product not done
1. Low oil temperature
2. Food basket overloaded
3. Cook time too short
1. Check cook temperature
2. Decrease load
3. Increase cook time
No flavor
1. Overcooked
2. Old product
1. Check cook time
2. Discard
White spots 1. Food basket overloaded 1. Decrease load size
Dark spots 1. Dirty oil 1. Filter or replace oil