9.14 Panel Unit
9.14.1
Panel Unit
(1) Remove the four taptite cup B M3x10 screws.
(2) Release the claw to remove the panel unit.
(3) Disconnect the connector of the panel harness ASSY from the panel PCB ASSY.
Fig. 3-51
Note:
Be careful not to pull the panel unit generic strongly because the harness is
connected to it.
Taptite cup B M3x10
Taptite cup B M3x10
Panel unit
Panel PCB ASSY
Connector
(Panel harness ASSY)