[ 2 ] Scanner mechanism
Defective component Result Error codes
CIS unit - Any of the following images may appear on the printout:
- When the power is turned on, abnormal noises will be
heard from the machine.
- Any of the following errors occurs:
- Dark level offset data level error for scanning
- Gain control data level error for scanning
- Scan area right/left edge detection error
- Horizontal scanning edge reduction/enlargement
detection error in scanning area setting
- White/black level data error
- Scan starting edge detection error
BD, AF
CIS flat cable - When the power is turned on, the "Init Unable AF"
appears on the LCD.
AF
Scanner drive unit - When the power is turned on, abnormal noises will be
heard from the machine.
---