4. ADJUSTMENT
HE-800A
84
Needle plate thickness Application Gauge
Clothing
(-2)
Knitted
wear
S13595-001 Gauge 815-2
Knitted
wear
(-3)
S13596-001 Gauge 815-3
Thin knitted
wear
S13597-001 Gauge 805-2
4-6-1. Adjusting the clearance between needle and hook point
Loosen the set screws (3) and move the rotary hook (4) forward or back until there is a clearance of 0.01 to 0.08 mm
between the needle (1) and the hook point (2).
* When tightening the set screws (3), tighten the one on the screw stop side first.
4293Q
4292Q
4296Q
4295Q
4294Q
2840Q
Screw stop side
2839Q
0.01 – 0.08 mm