3-54
Confidential
(4) Disconnect the connectors of the center thermistor harness ASSY and side thermistor
harness ASSY from the eject sensor PCB ASSY.
(5) Release the harnesses of the center thermistor harness ASSY and side thermistor
harness ASSY from the guides of the main frame L ASSY.
Fig. 3-42
Harness routing : Refer to "11. Fuser unit".
Center thermistor harness ASSY
Side thermistor
harness ASSY
Guide
Guides
Center thermistor
harness ASSY
Side thermistor
harness ASSY
Main frame L ASSY
Eject sensor PCB ASSY
Eject sensor PCB ASSY