10- 20 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical systems – 5000 LPE 240
Error codes
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
Code E107
Description Contactor K10 does not close.
Possible error
cause
Problem with main contactor points or coil.
Contactor’s operating cabling off/not connected.
Interruption in the travel regulator’s output, A1/4.
Action 1. Check if the contactor is activated.
2. If the contactor is working, check the contact
points and accompanying cabling.
3. If the contactor is not working, check the coil
and accompanying cabling. Measure Ohms
for the coil. Value 25-30 ohm.
4. Check the travel regulator’s output, A1/4.