EasyManua.ls Logo

BT LPE200 - Instructions for Verifying Parameter Setting

BT LPE200
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9- 42 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Parameters
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
Instructions for verifying parameter setting
Charge up the battery
Use the truck in its normal application until the battery indicator
shows an empty battery (0% on the display).
Remove the battery from the truck and allow to rest for at least two
hours. NB! No charging or discharging during this period.
Measure the acid weight of the battery at room temperature. If the
acid weight is less than 1.15 g/cm
3
, the parameter value must be
reduced. If the value significantly exceeds 1.15 g/cm
3
, the risk of
damage to the battery is reduced. At the same time, the operating
time of the truck is reduced. If a longer operating time is required, the
parameter value can be increased. Maximum one unit.
Each change must be accompanied by a new verification of the pa-
rameter setting.